GENERATOR
technical characteristics

Rated voltage, B. .................................... 14 The power of the nominal current, A. .................................... 50 At an ambient temperature (20 ± 5) ° C, generator, unheated state with independenxtexcitation of 12.5 V, should have the following characteristics. A. Rotor speed at which the voltage reached 12.5 V, 1 \ minutes, no more than: at a current load of O. ................... 950 at a current load of 32 A. ................ 2100 Two. Regulated voltage at ambient temperature (20 ± 5) ° C generator rotor speed 3500 1 \ min and the power of the load current 16 A connected to the battery must be in: for climatic modification W. ................. 13,7-14,4 for the climatic performance of T. ................. 13,2-13,9 Alternator with built-in integral 29.3701 device JA112A and rectifier unit BPV4-60 is designed to supply electricity consumers, and charging the battery. The generator is a three-phase synchronous electric machine with integrated rectifier unit with lingering ventilation. Built-in device is an integral voltage regulator. The generator operates in a single-wire electrical circuit with the addition of O - in the case. The generator has the following conclusions: "+" - To connect to the battery and the load; "W" - for connection to the ignition switch; "-" - For connection to the motor housing. Schematic dixagram of the connection of the generator 29.3701 on the car shows in Fig. 201. Longitudinal section of the generator is shown in Fig. 202. The efficiency of the generator and the length of service may be ensured only if all the rules of the installation, operation, maintenance outlined in this book. WARNING! Perform disconnection and connection of wires to generator only when the battery is disconnected. Work generator with the battery disconnected is not allowed. Proper operation of the generator and the regulator can be achieved only when provided good electrical xcontact between the buildings of the generator and regulator voltage. Perform repairs, maintenance, disassembly and reassembly of the generator a special workshop by qualified personnel. Perform testing rectifier unit only from DC current voltage noxtexceeding 24 V, connected in series with a test lamp. Москвич-412 Москвич-412
©2010-2017 Сайт Николая Русина.