SITE OF NICHOLAS RUSIN -

- PAINTING, SCULPTURE, PROSE AND MORE WHAT THAT


MAIN


LEAVE YOUR COMMENTS
ON THE PAGE OF OUR FORUM

Rare-OLD CARS

MOSKVICH-412

Сайт для инженеров и механиков

REPAIR lubrication system.
Checking the details of the oil pump drive mechanism

(See the section "Removal and installation of machinery drive the oil pump and distributor "). After removal check the following details: - Wear of the tooth driven gear drive; - The gap between the base plate and the end face of the housing; - Radial clearance between the bore casing and roller drive. Wear of teeth on the profile is determined by measuring the thickness of the tooth zabomerom. When worn teeth on the thickness more than 0.15 mm from the original thicknesses, gear be replaced by a new one. Allowed for the further operation of the gap between the end and support the puck should be no more than 0.25 mm. Permissible radial clearance of the hole for the shaft listed in Table 2.